Keywords

Swine day, 2000; Kansas Agricultural Experiment Station contribution; no. 01-138-S; Report of progress (Kansas State University. Agricultural Experiment Station and Cooperative Extension Service); 858; Swine; Indoor air quality; Livestock buildings; Airborne contaminants

Abstract

Air quality was assessed in two commercial swine-finishing barns: one naturally ventilated (NV) and one mechanically ventilated (MV). The concentrations of inhalable dust (IDC), respirable dust (RDC), airborne viable particles, carbon dioxide (CO2), and ammonia (NH3), as well as the air temperature and relative humidity (RH) inside the barns were monitored for 41 weeks. The two barns did not differ significantly (P>0.05) in IDC, RDC, and bioaerosol concentration. Overall mean levels for IDC, RDC, CO2, and NH3 were below the threshold limit values specified by the American Conference of Governmental Industrial Hygienists (ACGIH). However, some measurements exceeded the exposure limits suggested by previous researchers, especially during cold days. In general, the air quality in the two types of buildings was acceptable except under certain conditions (e.g., low ventilation rates during cold weather). In such case, workers and producers may need help or further training to ensure adequate air quality. In addition, under these conditions, workers should wear respiratory protective devices to minimize risk of inhalation of dust, gases, and bioaerosols.; Swine Day, Manhattan, KS, November 16, 2000

COinS
 

Rights Statement

In Copyright - Educational Use Permitted.
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.